當前位置 > 首頁 > 技術文章 > 生物技術等級透析膜應用介紹Spectra/Por® Dialysis Tubing

生物技術等級透析膜應用介紹Spectra/Por® Dialysis Tubing

瀏覽次數:5706 發布日期:2010-8-19  來源:本站 僅供參考,謝絕轉載,否則責任自負
At one time or another most scientists working in the ‘biochemical’ sciences will have to dialyze something. Dialysis is a simple technique to exchange a solute’s solution or to separate/purify differently sized molecules. Macromolecules are dialyzed by placing them in size-selective permeable tubing and subsequently equilibrating the sample with large volumes of new buffer: efficient dialysis relies upon appropriate selection of dialysis tubing and effective ‘washing’ that results from large volumes, multiple changes and full equilibration with the new buffer. I have recently been generating many fluorescent analogs of proteins and have used dialysis to remove ammonium sulfate from protein suspensions prior to labeling and to remove unincorporated succinimidyl esters of various fluorophores after labeling. For these steps I have been using Spectra/Por® dialysis tubing from Spectrum Laboratories®.
Spectra/Por® dialysis tubing is made of either regenerated cellulose (RC) or cellulose ester (CE). Cellulose has long been used for dialysis as it is uncharged and does not readily absorb solutes. Further, the selectivity of cellulose membranes is not altered greatly by many chemicals or reasonable pH and temperature ranges. Processed cellulose has crystalline regions and these regions cross-link chains to introduce structural integrity to the cellulose. Depending upon how the cellulose is processed the number of crystalline areas varies and the resultant regions between the cross-links can act like size-selective pores.
 
Many Spectra/Por® membranes are available with molecular weight cut offs (MWCO) from as little as 0.1 kDa all the way up to 300 kDa (CE membranes come in 0.1, 0.5, 1, 10, 100 and 300 kDa MWCOs, basic RC membranes come in 3.5, 6–8 and 12–14 kDa MWCOs and more expensive RC membranes have a range of MWCOs from 1–50 kDa). MWCO values are established by Spectrum® and represent the size at which a solute is 90 % retain during a test period. The small pore sizes available mean that relatively small molecules can easily be processed and I have used dialysis to buffer exchange samples of ~10 kDa with only minimal sample loss. Certain parameters such as pH may however alter MWCOs and so appropriate tubing needs to be established for a particular situation. That said, with my application using simple buffers the MWCOs have proven to be robust. Spectrum suggest that efficient separation can be achieved if the size ratio of the moieties is at least 25, this ratio is easy to achieve for buffer exchange of a protein or removal of unincorporated fluorescent dyes when labeling macromolecules. Equilibration of the membranes is relatively quick, especially for the larger pore sizes that I typically use, for instance, after labeling I can detect unincorporated dye molecules in my equilibration buffer within 2–4 hours during the first wash. This equilibration time means that 4 buffer changes can easily be performed in 24 hours.
 
Spectra/Por® is supplied in an essentially ready-to-go format, no boiling in bicarbonate buffer is needed. Spectra/Por® 1–6 merely need soaking in distilled water for 30 minutes whereas other tubing is supplied pre-hydrated and must be stored at 4 °C. One concern is that these membranes contain trace amounts of heavy metals and sulfur although Spectrum® do also produce specific cleaning solutions and supply Spectra/Por® 7 which comes with minimal contaminants. Membranes can be sterilized and also have two year shelf lives. Finally, Spectra/Por® tubing is supplied in different widths depending upon the scale of dialysis you plan.
 
For me dialysis essentially provides a ‘low maintenance’ way to perform buffer exchange or purify a sample if there is a large size differential. Other methods do exist to perform the same task including ultra-filtration units that are faster and extremely convenient. Dialysis is however, much more cost effective and so if I am not in a hurry for a sample I tend to use it. Further, dialysis does not rely on concentration of a sample and so may be more ‘gentle’ for your sample. The Spectra/Por® range of tubing definitely proves reliable, cost effective and widely applicable.
 
Peter Haggie, Ph.D.
Post-Doctoral Fellow
University of California, San Francisco
 
更多詳情請查閱
發布者:博傲西騰醫療科技(上海)有限公司
聯系電話:021-50720328
E-mail:58837581@qq.com

用戶名: 密碼: 匿名 快速注冊 忘記密碼
評論只代表網友觀點,不代表本站觀點。 請輸入驗證碼: 8795
Copyright(C) 1998-2025 生物器材網 電話:021-64166852;13621656896 E-mail:info@bio-equip.com
主站蜘蛛池模板: 欧美日韩在线精品一区二区三区激情福利综合 | 亚洲中文字幕无码中文字 | 青青国产揄拍视频在线观看 | 超碰pron人人| 好硬啊进得太深了A片无码公司 | 亚洲成A人在线看天堂无码 日本免费一区二区三区最新vr | 久视频精品线在线观看 | 四虎永久在线精品免费网址 | 美女视频黄的免费视频网页 | 国产欧美日韩高清 | 青楼妓女禁脔道具调教SM | 国产女人十八毛片A级毛片 国产成人无码VA在线观看 | 老黄色片 | 亚洲成A人在线看天堂无码 日本免费一区二区三区最新vr | 久久久精品久久久欧美俄罗乱妇 | 亚洲成A人片在线观看中文 国产在线视频91 | 亚洲中文无码一区二区三区在线观看 | 都市激情 在线 亚洲 国产 | 久久精品亚洲一区二区三区画质 | 国产太嫩了在线观看 | 丰满的人妻HD高清日本 | 国产wwwcom| 国产午夜无码片免费 | 一区二区狠狠色丁香久久婷婷 | 久久久国产一区二区三区四区小说 | 国产午夜av秒播在线观看 | 麻婆传媒 | 苍井苍空A免费井线在线观看 | 成人免费va视频 | 亚洲AV无码一区二区三区18 | 视频在线播 | 欧美人与动牲交ZOOZ乌克兰 | 亚洲r成人av久久人人爽 | 337p日本欧洲亚洲大胆精品555588 | 欧美性做爰片免费视频看 | 美女人妻激情乱人伦 | 亚洲va欧美va国产va影院 | 亚洲国产精品成人综合色在线婷婷 | 久久人人爽人人爽人人片亞洲 | 国产麻豆VIDEOXXXX实拍 | 少妇无套进入10p |