Materials
· Luciferase Substrate:
 Luc1 Substrate (DTZ) (Meisen, Cat# CTCC-002-023)
 Luc2 Substrate (AkaLumine-HCl) (Meisen, Cat# CTCC-002-024)
 · DPBS (Dulbecco's Phosphate-Buffered Saline), without Ca2+ or Mg2+
·  Syringe Filter, 0.2µm
 

 
Substrate Preparation
1. Thaw the substrates at room temperature and dissolve in DPBS (no calcium or magnesium) to the suggested final concentration.
Luc1 Substrate (DTZ): 3 mM DTZ solution containing 8% glycerol, 10% ethanol, 10% hydroxypropyl-β-cyclodextrin, and 35% PEG-400 in sterile water;
Luc2 Substrate (AkaLumine-HCl): 15 mM AkaLumine-HCl in saline;
 
2. Inoculate lab animal according to one of the various methods detailed below. (Luc1 and Luc2 substrates are typically administered either intraperitoneally or intravenously.)
Suggested starting dose: 100µl of prepared substrates for a 20g mouse.
 
3. Wait 10-20 minutes before imaging for maximum luciferase signal plateau.
 
4. A kinetic study of luciferase should be performed for each animal model to determine the peak signal time and plateau phase.

Determining the Kinetic Curve
The kinetics of tissue biodistribution may be different for each animal model and experimental design. We recommend creating a kinetic curve for each system prior to conducting the experiment in order to determine the peak signal time for imaging the animal model after the substrate injection.
 
To generate a kinetic curve for luciferase activity in your model:
1. Inject the substrate via one of the proposed methods listed below (Intraperitoneal (IP) or Intravenous (IV)). If you need to sedate the animals before injection, be aware that it may slightly extend the kinetics (peak luciferase expression time). The biodistribution of Luc substrate may also be different depending on the route of administration.
 
2. For IP Injection
a. If you are able to inject into animals which are still awake, wait three minutes, then sedate by your method of choice (gas or injectable anesthesia).

b. Place sedated animals in imaging chamber and take the first image approximately five minutes post Luc substrate injection.
 
3. For IV Injection
a. Immediately sedate the animal ( if not already sedated ) by your method of choice (gas or injectable anesthesia).
 
b. Place sedated animals in imaging chamber and take the first image within first two minutes post substrate injection
 
4. Continue to take images every 5-10 minutes up to about 40-60 minutes for IP injected models (for IV injected models: image every 1-5 minutes up to 20-30 minutes) to generate a kinetic curve for luciferase expression in your model.
· Most injectable anesthesia will last 20-30 minutes and might require an additional dose for a full kinetic curve study!)
 
5. Choose the best time point to image your model from your kinetic curve. Many models reach their peak signal time approximately 10-20 minutes post IP injection and 2-5 minutes post IV injection.
 
Intraperitoneal Injection (IP) in mice
1. First locate the point of entry for the needle
 
2. Draw an imaginary line across the abdomen just above the knees (see image above).
 
3. The needle should be inserted along this line on the animal's right side and close to the midline. (The point of entry is cranial to and slightly medial of the last nipple in a female mouse.)
 
4. Inserting the needle on the mouse's right side avoiding the cecum, which is a large fluid-filled organ on the left side of the abdomen. The small intestines (on the right side) are less likely to be punctured by the needle.
 
5. Inserting the needle too far caudally or laterally from the insertion point shown above would risk making an injection into the rear leg which would injure the muscle tissue.
 
6. To perform an IP injection, the mouse must be well restrained so that it cannot move during the procedure. This avoids traumatizing the organs once the needle has entered the abdomen.
 
7. Restrain the mouse and tilt so that the head is facing downward and its abdomen is
exposed.
 
8. Thoroughly disinfect the injection site with 70% ethanol. 9. We recommend using
a 25-27-gauge needle for IP injections. Insert the needle into the abdomen at about
a 30-degree angle.
 
Intravenous Injection (IV) in mice
 

 
Restrain the mouse with physical or chemical restraint. Rotate the tail slightly to visualize vein. Disinfect injection site with 70% ethanol and insert the needle (27-30 gauge) into the vein at a slight angle. You will not be able to aspirate, instead inject slowly and watch for clearing of the lumen. Incorrect positioning will result in a slight bulge in the tail. If this occurs, remove needle and repeat process proximal to previous site. Upon completion, remove needle and apply pressure to injection site. Record the injection time to determine peak signal time.
發(fā)布者:浙江美森細(xì)胞科技有限公司
聯(lián)系電話:0571-86027729
E-mail:120977236@qq.com

用戶名: 密碼: 匿名 快速注冊(cè) 忘記密碼
評(píng)論只代表網(wǎng)友觀點(diǎn),不代表本站觀點(diǎn)。 請(qǐng)輸入驗(yàn)證碼: 8795
Copyright(C) 1998-2025 生物器材網(wǎng) 電話:021-64166852;13621656896 E-mail:info@bio-equip.com
主站蜘蛛池模板: 日韩欧美日韩在线 | 黑人大荫道BBWBBB高潮潮喷 | 99r国产精品| 特黄特色三级在线观看 | 精品无码人妻一区二区三区免费 | 亚洲精品视频播放 | 亚洲另类自拍小说图片 | 97久久偷偷做嫩草影院免费看 | 午夜一区在线观看 | 国产精品无码综合区 | 免费观看国产视频 | 国产嫩草视频 | 偷拍一区二区三区在线婷婷 | 色五月最新网址 | 亚洲成A人片在线观看无遮挡 | 无码精品乱伦国产 | av在线免费观看网 | 亚洲欧美日韩愉拍自拍 | 无翼乌口工全彩无遮挡老师 | 久久国产亚洲高清观看 | 久久国产精品色av免费观看 | 妺妺窝人体色777777野大粗 | 日本视频又叫又爽 | xxxxx亚洲| 免费网站看V片在线18禁无码 | 成人无码AV网站在线观看 | 2021全国产精品网站 | 日产精品一二三区 | 99热久久精里都是精品6软件介绍 | 东北露脸46熟妇ⅩⅩXX | 久久精品免费一区二区 | 亚洲在AV人极品无码 | 少妇被后进高潮动态图gif | 欧美性猛交xxxx乱大交免费看 | 久久久久久久久动漫 | 最新中文无码字字幕在线 | 日本不卡1区2区3区 精品一区二区三区国产在线观看 | 国产亚洲精品久久久久蜜臀 | 少妇被黑人4P到惨叫 | 天天摸天天碰天天添中文无码 | 色涩视频 |